Frequency Counters Specifications

A Proud South African CompanyMeasurements Group South Africa

EZ Digital

Measurements Group South Africa is the leading independent supplier of New, Used & Refurbished Test & Measurement Equipment. We deal in all major and minor brands such as Tektronix, Agilent/ (HP), Rhode & Schwarz, Marconi, Fluke and Major Tech. We offer Rentals and purchase quality used equipment outright or on a trade-in basis. Contact us for repairs and calibration to all makes of Test & Measurement Equipment

Used Test Equipment

Tel:

+2711 318 1895 / 391 4747

Mobile:

+2783 676 0231 / 83 264 1057

Fax:

+2711 318 1039 / 972 6005

Email:

sales@measuregroup.co.za

WE BUY, SELL, RENT, CALIB. & SERVICE ALL MAKES OF NEW & USED TEST EQUIP.

South Africa

EZ Digital FC 7015U 100MHz Universal Digital Frequency Counter

Frequency Range

A,B Input 0.1 Hz to 100MHz

 

Short term Stability

<3 x 10-7 per month

Display

9 Digits

Time Base

TCO (TCXO optional)

Measurement Technique

Reciprocal technique for High Resolution at low frequencies

Gate Time

0.01, 0.1, 1, 10 sec

Basic Sensitivity

> 20mV

External Time Base Input

10MHz

Input Impeadance

1MΩ Separate or Common (Selectable)

Interface

RS232 optional

Standard Functions

Frequency, Period, Time Interval, Ratio, Totalize,

 

 

EZ Digital FC 7150U 1.5GHz Universal Digital Frequency Counter

Frequency Range

A,B Input 0.1 Hz to 100MHz

C Input 1.5GHz

Short term Stability

<3 x 10-7 per month

Display

9 Digits

Time Base

TCO (TCXO optional)

Measurement Technique

Reciprocal technique for High Resolution at low frequencies

Gate Time

0.01, 0.1, 1, 10 sec

Basic Sensitivity

> 20mV

External Time Base Input

10MHz

Input Impeadance

1MΩ Separate or Common (Selectable)

Interface

RS232 optional

Standard Functions

Frequency, Period, Time Interval, Ratio, Totalize,

 

 

EZ Digital FC 7015 100MHz Digital Frequency Counter

Frequency Range

A,B Input 0.1 Hz to 100MHz

 

Short term Stability

<3 x 10-7 per month

Display

9 Digits

Time Base

TCO (TCXO optional)

Measurement Technique

Reciprocal technique for High Resolution at low frequencies

Gate Time

0.01, 0.1, 1, 10 sec

Basic Sensitivity

> 20mV

External Time Base Input

10MHz

Input Impeadance

1MΩ Separate or Common (Selectable)

Interface

RS232 optional

Standard Functions

Frequency, Period, Totalize, RPM

 

 

EZ Digital FC 7150 1.5GHz Digital Frequency Counter

Frequency Range

A,B Input 0.1 Hz to 100MHz

 

Short term Stability

<3 x 10-7 per month

Display

9 Digits

Time Base

TCO (TCXO optional)

Measurement Technique

Reciprocal technique for High Resolution at low frequencies

Gate Time

0.01, 0.1, 1, 10 sec

Basic Sensitivity

> 20mV

External Time Base Input

10MHz

Input Impeadance

1MΩ Separate or Common (Selectable)

Interface

RS232 optional

Standard Functions

Frequency, Period, Totalize, RPM